- Error code
- 6901
- Category
- Input B defective
- Manufacturer
- SMA
- Models
- Sunny Tripower (STP)
1What the error means
Self-diagnosis: a problem on DC input B, i.e. the second MPP tracker. The same applies as for input A — either the string or the inverter's input circuit.
2Possible causes
- Fault in the string on input B
- Fault in MPP tracker B
3What to do
- Measure the string on input B.
- Swap strings A and B to see whether the fault follows the PV generator or stays on the input.
Same code group
Code 6901 belongs to the same group as 6902 — they share the same cause and the same remedy.