SMA Error 6901

Input B defective

Error code
6901
Category
Input B defective
Manufacturer
SMA
Models
Sunny Tripower (STP)

1What the error means

Self-diagnosis: a problem on DC input B, i.e. the second MPP tracker. The same applies as for input A — either the string or the inverter's input circuit.

2Possible causes

  • Fault in the string on input B
  • Fault in MPP tracker B

3What to do

  1. Measure the string on input B.
  2. Swap strings A and B to see whether the fault follows the PV generator or stays on the input.

Same code group

Code 6901 belongs to the same group as 6902 — they share the same cause and the same remedy.