SMA Error 6501

Overtemperature

Error code
6501
Category
Overtemperature
Manufacturer
SMA
Models
Sunny Tripower (STP)

1What the error means

Self-diagnosis — overtemperature: the temperature inside the inverter exceeded the limit. The inverter reduces power or stops until it cools down.

2Possible causes

  • Dirty or blocked fans and heat sinks
  • Installation in an enclosed space without ventilation or in direct sun
  • Faulty fan or temperature sensor

3What to do

  1. Clean the heat sinks and check that the fans are turning.
  2. Ensure ventilation and shade at the installation site.
  3. If the fault appears with the unit cold, the sensor or the fan needs to be replaced.

Same code group

Code 6501 belongs to the same group as 6502 — they share the same cause and the same remedy.