SMA Error 3601

Leakage current

Error code
3601
Category
Leakage current
Manufacturer
SMA
Models
Sunny Tripower (STP)

1What the error means

The leakage current of the PV generator to earth is too high. The inverter disconnects for safety reasons.

2Possible causes

  • Moisture in modules, junction boxes or connectors
  • Worn insulation on DC cables
  • High generator capacitance to earth in large plants

3What to do

  1. Check the DC cables and connectors for moisture and damage.
  2. Measure the insulation resistance of the PV generator.
  3. If the PV generator is fine, check the inverter's measuring circuit.