1What the error means
Code 6437 belongs to the event group 6001 to 6438. SMA documents this group as self-diagnosis, meaning an internal interference of the device. The inverter detected an anomaly during its internal check, often at start-up before connecting to the grid. For this reason it does not connect and does not feed in energy. The manufacturer does not assign a separate cause to each code in the group. The exact cause is identified through diagnosis in the workshop.
2Possible causes
- Fault on the power board
- Worn grid relay
- Fault in the measuring or control circuit
- Ageing of internal components due to thermal stress
3What to do
- Perform a full restart: disconnect the AC side and then the DC switch. Wait at least 5 minutes, then reconnect DC first and AC afterwards.
- Check the AC fuses and the AC cable connection at the inverter and in the distribution board.
- Note the code and when it appears, for example at start-up or during operation.
- If the fault persists after the restart, the inverter needs to be checked in the workshop.
4Repair by Aineas
You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.