- Error code
- 6416
- Category
- Internal device fault
- Manufacturer
- SMA
1What the error means
Code 6416 belongs to the event group 6001 to 6438, which SMA documents as "Self-diagnosis – Device fault". During its internal self-test, the inverter detected a malfunction in its own electronics and stops feeding in power as a protective measure. The manufacturer does not attribute an external cause to this code. The exact cause can only be identified by diagnosing the device in the workshop.
2Possible causes
- Fault on an internal control or power board
- Malfunction in a measuring circuit or sensor of the inverter
- Component wear due to ageing or high operating temperatures
- Stress on the device from overvoltages or lightning events
3What to do
- Disconnect the inverter first on the AC side (circuit breaker/switch) and then on the DC side (DC load-break switch). Wait a few minutes and reconnect in the reverse order.
- Check that the installation site is adequately ventilated and that the inverter is not exposed to overheating or moisture.
- Note whether the code reappears and under which conditions (time of day, power output, weather conditions).
- If the fault persists after the restart, the inverter needs to be checked in the workshop.
4Repair by Aineas
You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.
