SMA Error 3401

DC overvoltage

Error code
3401
Category
DC overvoltage
Manufacturer
SMA
Models
Sunny Tripower (STP)

1What the error means

The DC input voltage exceeded the inverter's maximum permitted voltage. This is a dangerous condition: the inverter disconnects so that its input is not destroyed.

2Possible causes

  • Too many modules in series for this model
  • Very low temperature — the open-circuit voltage rises in winter

3What to do

  1. Disconnect the PV generator immediately.
  2. Check the number of modules per string against the maximum input voltage.
  3. If the inverter ran with overvoltage, its input needs to be checked for damage.

Same code group

Code 3401 belongs to the same group as 3402 — they share the same cause and the same remedy.