DC current at the output

Error code
601
Category
DC current at the output
Manufacturer
SMA
Models
Sunny Tripower (STP)

1What the error means

The inverter detected an excessively high DC component in the current it feeds into the grid. The standard requires immediate disconnection in order to protect the grid transformers.

2Possible causes

  • Fault in the power bridge (IGBT) or the capacitors
  • Fault in the current measuring circuit

3What to do

  1. Restart the inverter once.
  2. If the code returns, it is an internal fault and repair in our lab is required.

4Repair by Aineas

You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.