- Error code
- 6802
- Category
- Input A defective
- Manufacturer
- SMA
- Models
- Sunny Tripower (STP)
1What the error means
Self-diagnosis: the inverter detected a problem on DC input A, i.e. the first MPP tracker. The cause may be the string connected there or the input circuit itself.
2Possible causes
- Fault in the string on input A — voltage, polarity or short circuit
- Fault in the inverter's MPP tracker A
3What to do
- Measure the voltage and polarity of the string on input A.
- Try the same string on input B: if the fault moves, the PV generator is at fault; if it stays on A, the inverter is at fault.
Same code group
Code 6802 belongs to the same group as 6801 — they share the same cause and the same remedy.
4Repair by Aineas
You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.