SMA Error 302

Power limitation

Error code
302
Category
Power limitation
Manufacturer
SMA
Models
Sunny Tripower (STP)

1What the error means

The inverter is limiting its active power because of high grid voltage. It is not a fault: it reduces output so as not to raise the voltage at the point of connection any further. You will see reduced output during peak hours.

2Possible causes

  • High grid voltage at the point of connection
  • Large voltage drop on the AC cable
  • Several inverters on the same grid section

3What to do

  1. Measure the voltage at the point of connection while the inverter is feeding in.
  2. Check the cross-section and length of the AC cable.
  3. If the grid voltage is permanently high, notify the grid operator.