KACO OS 60

Low DC voltage

Error code
OS 60
Category
Low DC voltage
Manufacturer
KACO

1What the error means

The inverter does not start feeding in until the generator voltage drops below a set value. A waiting state, not a fault.

On the display or in the monitoring software it appears as OS 60.

2Possible causes

  • Low solar irradiance — morning, evening or overcast
  • Shading or soiling of the modules
  • Broken DC cable or faulty string
  • DC switch open

3What to do

  1. If it appears only at the start and end of the day, it is normal.
  2. Check that the DC switch is closed.
  3. Measure voltage and current on each string in sunshine.
  4. Check for shading, dirty modules and damaged DC connectors.