+30 2310 607032 · info@aineas.gr · Mon–Fri 09:00–17:00
Services The lab How it works Inverter Errors Contact thesolarportal.com thesolarlink. →

KACO FS 36

Internal fault

Error code
FS 36
Category
Internal fault
Manufacturer
KACO

1What the error means

Protective shutdown by the hardware, on AC over-voltage or over-current or DC link over-voltage. A hardware shutdown indicates a more serious event than the corresponding software one.

On the display or in the monitoring software it appears as FS 36.

2Possible causes

  • Fault on the power or control board
  • Worn capacitors
  • Damage from overvoltage — lightning or grid

3What to do

  1. Switch off AC and DC, wait 2–3 minutes and restart once.
  2. If the code returns, it cannot be fixed on site — it needs diagnosis in our lab.

4Repair by Aineas

You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.

← All KACO errors