KACO FS 58

Overtemperature

Error code
FS 58
Category
Overtemperature
Manufacturer
KACO

1What the error means

The temperature inside the device was too high. The inverter shuts down to prevent damage to the hardware.

On the display or in the monitoring software it appears as FS 58.

2Possible causes

  • Dirty or blocked heat sinks and fans
  • Installation in an enclosed space without ventilation or in direct sun
  • Faulty fan or temperature sensor

3What to do

  1. Clean the heat sinks and check that the fans are turning.
  2. Ensure ventilation and shade at the installation site.
  3. If the fault appears with the unit cold, the sensor or the fan needs to be replaced.