KACO FS 32

Grid relay

Error code
FS 32
Category
Grid relay
Manufacturer
KACO

1What the error means

The internal check of the grid disconnection relay failed. The inverter does not connect if the relay fails the check.

On the display or in the monitoring software it appears as FS 32.

2Possible causes

  • Stuck or burnt relay contacts
  • Fault in the relay drive circuit
  • Wear after many switching cycles

3What to do

  1. One restart with AC and DC switched off.
  2. If it returns, the relays need to be replaced in our lab.

4Repair by Aineas

You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.

← All KACO errors