- Error code
- FS 18
- Category
- Leakage current
- Manufacturer
- KACO
1What the error means
Leakage current was detected and grid feed-in was interrupted immediately.
On the display or in the monitoring software it appears as FS 18.
2Possible causes
- Ground fault in the PV generator
- Moisture in the installation
- Faulty module or cable
- Fault in the inverter's residual current sensor
3What to do
- Check the PV generator for a ground fault, especially after rain.
- Measure the insulation resistance.
- If the fault also appears with the PV generator disconnected, the fault is in the inverter.
4Repair by Aineas
You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.
