KACO FS 38

DC overvoltage

Error code
FS 38
Category
DC overvoltage
Manufacturer
KACO

1What the error means

The PV generator voltage is too high — the generator is configured incorrectly, with more modules in series than the inverter can withstand.

On the display or in the monitoring software it appears as FS 38.

2Possible causes

  • Too many modules in series for this model
  • Low temperature — the open-circuit voltage rises in winter
  • Incorrect string sizing

3What to do

  1. Disconnect the PV generator immediately.
  2. Check the number of modules per string against the maximum input voltage.
  3. If the inverter ran with overvoltage, its input needs to be checked for damage.

4Repair by Aineas