REFUSol Inverter Error Codes

Most Common Inverter Faults

REFUsol inverter repair — which models we take on and how we work →

The most common faults on REFUSOL inverters

On many REFUSol inverters, errors appear that relate to the incorrect operation of your inverter.
Try switching off the grid breaker and switching it back on after 2-3 minutes.
If the problem persists, you will need to send us the inverter for repair.
You can call us on +30 2310 607032 for any related information.
254 codes
ErrorCauseAction
0x000000An error may have been acknowledged while this was not permittedError management — Error may have been acknowledged although this was not permissible. No other explanation can be provided for error.Details → 0x090006Grid over-voltage — phase over-voltage (AC) detectedGrid overvoltage — Phase overvoltage (AC) has been detected.Details → 0x090007Grid over-voltage — phase over-voltage (AC) detectedGrid overvoltage — Phase overvoltage (AC) has been detected.Details → 0x090008Over-frequency — the grid frequency exceeded the limitOverfrequency — The grid frequency has exceeded the limit value.Details → 0x090009Under-frequency — the grid frequency dropped below the limitUnderfrequency — The grid frequency has dropped below the limit value.Details → 0x09000AFault in the DC linkDC link 3 — Dc-voltage measurement error.Details → 0x09000BFault in the DC linkDC link 1 — Imbalance low: Difference between the DC link voltages is too high.Details → 0x09000CFault in the DC linkDC link 2 — Imbalance high: Difference between the two boosted DC link voltages is too highDetails → 0x09000DFault in the DC linkDC link 4 — The boosted DC-voltage has dropped below the mains peak valueDetails → 0x09000FVoltage fault in the regulator circuit / DC link 13Regulator voltage 13 — The DC-voltage has dropped below the mains peak valueDetails → 0x090010Fault in the DC linkDC link 5 — The boosted DC link voltage is too high.Details → 0x090011Fault in the DC linkDC link 6 — The DC link voltage is too high.Details → 0x090017Communication error between the power stage and the control unitCommunication LT — Communication malfunction between power section and control and regulation unitDetails → 0x090018The power stage detected grid over- or under-frequencyGrid frequency LT — Power section has detected under/overfrequencyDetails → 0x090019Grid over-voltage — the power stage detected a phase over-voltageGrid overvoltage LT — The power section has detected a phase overvoltage.Details → 0x09001AGrid under-voltage — the power stage detected a phase under-voltageGrid undervoltage LT — The power section has detected a phase undervoltage.Details → 0x09001BThe RCD circuit detected leakage current — immediate disconnectionRCD fault — The AFI-Board unit has detected a residual current. Leads to an immediately shutdownDetails → 0x09001DThe RCD circuit detected leakage current — warning with immediate disconnectionRCD warning — The AFI-Board unit has detected a residual current. Leads to an immediately shutdown.Details → 0x090020Initialisation failedInitialisation C1 — Initialisation has failed.Details → 0x090021Initialisation failedInitialisation C0 — Initialisation has failed.Details → 0x090022Internal device checkTest perm. FaultDetails → 0x090023A critical error occurred repeatedly — the device was permanently shut downPermanent fault — A critical fault has repeatedly occurred. The device has been permanently shut down.Details → 0x090024Error during parameter initialisation — the device was permanently shut downSR parameter error — Error in parameter initialisation. The device has been permanently shut down.Details → 0x090025Internal device check: MQXTS invalid: MQXDetails → 0x090026Internal device check: RAMTS invalid: RAMDetails → 0x090027Internal device check: RTCTS invalid: RTCDetails → 0x090028Firmware update notificationUpdate Start — Update start notification.Details → 0x090029Firmware update failedUpdate fault — Update failedDetails → 0x09002AInternal communication monitoring detected an errorKeep Alive — Internal communication monitoring has determined a fault.Details → 0x09002BFirmware update notificationUpdate End — Update successful notification.Details → 0x09002CIslanding detected (phase shift) — the grid section was cut off and the inverter disconnectedAntiIslandPhaseShift — Islanding of the connected grid section has been detectedDetails → 0x09002DIslanding detected (RoCoF) — the grid section was cut off and the inverter disconnectedAntiIslandRocof — Islanding of the connected grid section has been detectedDetails → 0x09002FInternal data can no longer be writtenFFS is read-only — Internal data can’t be written anymore.Details → 0x090030The DC component in the output current exceeds the permitted limitDC share too high — The measured DC-Part in AC current exceed the defined limit.Details → 0x090031The Ethernet cable was disconnectedETH link lost — The Ethernet cable has been removedDetails → 0x090032The device restartedRestart — The system has been rebooted.Details → 0x090033Fault in the power stage (restart or wrong component configuration)LT watchdog reset — LT reset.Details → 0x090051The switch-on conditions of the DC side are not metDC condition — DC switch on condition not fulfilledDetails → 0x090052The inverter does not connect to the grid because the user lock is activeUser lock active — The inverter can’t connect to the grid, as the User-lock has been set.Details → 0x090053Communication error between the power stage and the control unitCommunication SR — Internal communication problemsDetails → 0x090054The phase voltage exceeded the average voltage limit for too longOvervoltage 2 — The phase voltage has exceeded the limit value of the voltage average monitor for too long.Details → 0x090055Grid over-voltage — phase over-voltage (AC) detectedGrid overvoltage — Line-to-line overvoltage (AC) detectedDetails → 0x090056Grid under-voltage — under-voltage between phases (AC) detectedGrid undervoltage — Line-to-line undervoltage (AC) detectedDetails → 0x090057Internal protection function (watchdog) C0 was triggeredWatchdog C0 — Internal protection function is triggered.Details → 0x090058Internal protection function (watchdog) C1 was triggeredWatchdog C1 — Internal protection function is triggered.Details → 0x090059Defective firmware of the power stageLT Firmware — The software of the LT is defective.Details → 0x090060Grid instability handled according to the grid codeFRT stability — Stability issue with the DC link detected.Details → 0x090061Firmware update failedUpdate fault — This notification can be ignored.Details → 0x090062Grid instability handled according to the grid codeFault ride through — Grid-instability which is handled with respect to the grid code standards.Details → 0x090063No change in the insulation current was measured during the testPV-isolation SR — No change in the insulation-current could be measured during the insulation-test.Details → 0x090070Over-current in one of the stringsString overcurrent — Over current on one of the stringsDetails → 0x0A0000Wrong FPGA firmware versionFPGA firmware — Incorrect FPGA versionDetails → 0x0A0001Voltage fault in the regulator circuit / DC link 1Regulator voltage 1 — Dc-voltage measurement error.Details → 0x0A0002Voltage fault in the regulator circuit / DC link 2Regulator voltage 2 — Dc-voltage measurement error.Details → 0x0A0003Voltage fault in the regulator circuit / DC link 3Regulator voltage 3 — Imbalance low: Difference between the DC link voltages is too high.Details → 0x0A0004Voltage fault in the regulator circuit / DC link 4Regulator voltage 4 — Imbalance high: Difference between the two boosted DC link voltages is too highDetails → 0x0A0005Voltage fault in the regulator circuit / DC link 5Regulator voltage 5 — The positive boosted DC-voltage has dropped below the mains peak valueDetails → 0x0A0006Voltage fault in the regulator circuit / DC link 6Regulator voltage 6 — The negative boosted DC-voltage has dropped below the mains peak valueDetails → 0x0A0007Voltage fault in the regulator circuit / DC link 7Regulator voltage 7 — The positive DC link voltage has dropped below the limit value.Details → 0x0A0008Voltage fault in the regulator circuit / DC link 8Regulator voltage 8 — The positive DC link voltage is too high.Details → 0x0A0009Voltage fault in the regulator circuit / DC link 9Regulator voltage 9 — The negative DC link voltage has dropped below the limit value.Details → 0x0A000AVoltage fault in the regulator circuit / DC link 10Regulator voltage 10 — The negative DC link voltage is too high.Details → 0x0A000BVoltage fault in the regulator circuit / DC link 11Regulator voltage 11 — The positive boosted DC link voltage is too high.Details → 0x0A000CVoltage fault in the regulator circuit / DC link 12Regulator voltage 12 — The netagive boosted DC link voltage is too high.Details → 0x0A000DGrid over-voltage — phase over-voltage (AC) detectedGrid overvoltage — Phase overvoltage (AC) has been detected.Details → 0x0A000EGrid under-voltage — under-voltage between phases (AC) detectedGrid undervoltage — Phase undervoltage (AC) has been detected.Details → 0x0A000FGrid over-voltage between phases (line-to-line voltage)Grid overvlt. l2l — Line-to-line overvoltage (AC) detectedDetails → 0x0A0010Grid under-voltage between phases (line-to-line voltage)Grid undervlt. l2l — Line-to-line undervoltage (AC) detectedDetails → 0x0A0011Grid fault detected by the frequency monitoring circuitGrid frequency FLL — A grid error has been detected (FLL).Details → 0x0A0012Over-frequency — the grid frequency exceeded the limitOverfrequency — The grid frequency has exceeded the limit value.Details → 0x0A0013The measured leakage current exceeded the safety limitsPM isolation RCD SR — The measured value of the residual currents are over the limits: Measured value >150 mA -> Trip within 20 ms Measured value >60 mA -> Trip within 130 ms Measured value >30 mA -> Trip within 280 msDetails → 0x0A0014The country code is not set or is invalidNo country code — No country code has been set, or code invalid.Details → 0x0A0016Under-frequency — the grid frequency dropped below the limitUnderfrequency — The grid frequency has dropped below the limit value.Details → 0x0A0017The country code is not set or is invalidInvalid country — Invalid country codeDetails → 0x0A0018The average grid voltage stayed above the limit for too longVoltage error max — The nominal grid voltage was above the limit value of the voltage average monitor for too long.Details → 0x0A0019The average grid voltage stayed below the limit for too longVoltage error min — The nominal grid voltage was below the limit value of the voltage average monitor for too long.Details → 0x0A0020External monitoring caused a disconnectionExternal cut-off — External monitoring has triggered a disconnection.Details → 0x0A0021Arc fault detection caused a disconnectionARC fault detected — Arc fault detection has triggered a disconnectionDetails → 0x0A0022External OVGR cut-off signal detectedExt. OVGR Signal — External stop signal OVGR is detected.Details → 0x0A0023Islanding detected — the grid section was cut off and the inverter disconnectedRoCoF — RoCoF failure is detectedDetails → 0x0A0024Islanding detected — the grid section was cut off and the inverter disconnectedActive Islanding — Island situation detected.Details → 0x0A0025Power reduction due to high grid voltage, P(V)P(V) Start — High AC Voltage, P(V) Derating EntryDetails → 0x0A0026Power reduction due to high grid voltage, P(V)P(V) End — High AC Voltage, P(V) Derating EndedDetails → 0x0A0100Fault message from the power stageFault message LT — Fault message from power sectionDetails → 0x0A0102Over-temperature in the power stage (sensor 1)Overtemperature LT 1 — Cooler overtemperature (right)Details → 0x0A0103Over-temperature in the power stage (sensor 2)Overtemperature LT 2 — Interior overtemperature (left)Details → 0x0A0104Over-temperature in the power stage (sensor 3)Overtemperature LT 3 — Interior overtemperature (right)Details → 0x0A0105Over-temperature in the power stage (sensor 4)Overtemperature LT 4 — Cooler overtemperature (left)Details → 0x0A0106Defective supply voltage in the power stageSupply voltage LT — Supply voltage at the power section is too low.Details → 0x0A0108The power stage detected grid over- or under-frequencyGrid frequency LT — Power section has detected under/overfrequency.Details → 0x0A0109Grid over-voltage — the power stage detected a phase over-voltageGrid overvoltage LT — The power section has detected a grid overvoltage.Details → 0x0A010AGrid under-voltage — the power stage detected a phase under-voltageGrid undervoltage LT — The power section has detected a grid undervoltage.Details → 0x0A010CThe power stage detected an insulation fault during activationPM isolation LT — Power section detects an isolation error on activation.Details → 0x0A010DThe RCD circuit detected leakage current — immediate disconnectionRCD fault — The power section has detected residual current. Isolation error during operation.Details → 0x0A010EHardware shutdown of the power stageDevice fault LT — Power section hardware shutdownDetails → 0x0A0110Shutdown of the power stage due to DC over-voltageSolar voltage LT 1 — Power section overvoltage shutdown in positive DC linkDetails → 0x0A0111Shutdown of the power stage due to DC over-voltageSolar voltage LT 2 — Power section overvoltage shutdown in negative DC linkDetails → 0x0A0113The country code does not match the country sub-codeCountry code LT — Country code does not correspond to country sub-code.Details → 0x0A0114The measured leakage current exceeded the safety limitsPM isolation RCD LT — Residual current measured from the LT exceeded the limits. residual current > Limit values of 20 mA, 130mA, 280mA respectivelyDetails → 0x0A0115The RCD circuit detected leakage current — warning with immediate disconnectionRCD warning — The power section has detected residual current during operation.Details → 0x0A0116Internal device checkR-detectDetails → 0x0A0117The insulation test is taking too longIsolation test unit — Test isolation test is taking too long.Details → 0x0A0118Calibration values differ between the power stage and the control unitVoltage offset LT — Offset adjustment values between power section and control and regulation unit divergentDetails → 0x0A0119The current transducer detected no current flow at allCurrent transdcr. LT — Current transducer could not detect any current flow.Details → 0x0A011AFailure in the activation sequence of the power stageActivation LT 1 — Voltage booster self-test failed.Details → 0x0A011BFailure in the activation sequence of the power stageActivation LT 2 — DC link voltage drop during activationDetails → 0x0A011CFailure in the activation sequence of the power stageActivation LT 3 — Target value for balancing is invalid.Details → 0x0A011DFailure in the activation sequence of the power stageActivation LT 4 — Balancing has failed.Details → 0x0A011EFailure in the activation sequence of the power stageActivation LT 5 — Voltage booster mailfunctionDetails → 0x0A011FParameter error — defective read, write or parameter fileParameter error LT 5 — Faulty reading or writing process in power section memoryDetails → 0x0A0120Communication error between the power stage and the control unitCommunication LT — Communication malfunction between power section and control and regulation unitDetails → 0x0A0121The DC component in the output current exceeds the permitted limitDC component — The DC component of the AC-Current is too high.Details → 0x0A0130Fault in the power stage (restart or wrong component configuration)LT elements — Faulty configuration of elements for the power sectionDetails → 0x0A0131The coupling relay failed to switch — possible over-voltage of the generatorArray Overvoltage — Switching the combine relay has failed. Possible array overvoltage.Details → 0x0A0150Over-temperature — the temperature exceeded the set limit (2)Overtemperature 2 — The temperature has exceeded the parametrised limit value.Details → 0x0A0151Over-temperature — the temperature exceeded the set limit (AC1)Overtemperature AC1 — The temperature has exceeded the parametrised limit value.Details → 0x0A0152Over-temperature — the temperature exceeded the set limit (AC2)Overtemperature AC2 — The temperature has exceeded the parametrised limit value.Details → 0x0A0153Over-temperature — the temperature exceeded the set limit (inner)Overtemp., inner — The temperature has exceeded the parametrised limit value.Details → 0x0A0154Over-temperature on the heat sink of boost converter 1Overtemperature DC1 — The cooler temperature at the positive boost converter exceeds the limit value.Details → 0x0A0155Over-temperature on the heat sink of boost converter 2Overtemperature DC2 — The cooler temperature at the negative boost converter exceeds the limit value.Details → 0x0A0156Over-temperature — the temperature exceeded the set limit (U)Overtemperature U — The temperature has exceeded the parametrised limit value.Details → 0x0A0157Over-temperature — the temperature exceeded the set limit (V)Overtemperature V — The temperature has exceeded the parametrised limit value.Details → 0x0A0158Over-temperature — the temperature exceeded the set limit (W)Overtemperature W — The temperature has exceeded the parametrised limit value.Details → 0x0A0159Fault in fan 1Fault fan 1 — Fault message from fan 1Details → 0x0A015AFault in fan 2Fault fan 2 — Fault message from fan 2Details → 0x0A015BFault in fan 3Fault fan 3 — Fault message from fan 3Details → 0x0A015CFault in fan 4Fault fan 4 — Fault message from fan 4Details → 0x0A015DFault in fan 5Fault fan 5 — Fault message from fan 5Details → 0x0A015EWire break in the heat sink temperature sensorNTC wire break — Cooler sensor has detected a wire break.Details → 0x0A015FShort circuit in the heat sink temperature sensorNTC short circuit — Cooler sensor has detected a short circuit.Details → 0x0A0160Error during prechargingPreload error — Error has occurred during preload.Details → 0x0A0161Over-current in the boost circuit — hardware shutdown.Overcurrent HSS pos. — Hardware shutdown caused by overcurrent in the positive circuit of the boost converterDetails → 0x0A0162Over-current in the boost circuit — hardware shutdown.Overcurrent HSS neg. — Hardware shutdown caused by overcurrent in the negative circuit of the boost converterDetails → 0x0A0163Over-current on phase U — hardware shutdownOvercurrent U phase — Hardware shutdown caused by U-phase overcurrentDetails → 0x0A0164Over-current on phase V — hardware shutdownOvercurrent V phase — Hardware shutdown caused by V-phase overcurrentDetails → 0x0A0165Over-current on phase W — hardware shutdownOvercurrent W phase — Hardware shutdown caused by W-phase overcurrentDetails → 0x0A0166Over-voltage in the DC linkOvervolt. DC-l. pos. — Overvoltage has been detected in the positive DC link voltage.Details → 0x0A0167Over-voltage in the DC linkOvervolt. DC-l. neg. — Overvoltage has been detected in the negative DC link voltage.Details → 0x0A0168Incorrect connection of the input current groupsString error — Input current groups connected incorrectlyDetails → 0x0A0169Wire break in the insulation sensorIso wire break — Isolation sensor has a wire breakDetails → 0x0A016AAsymmetric power output on the three phasesPhase Unbalance — Unbalanced power delivery.Details → 0x0A016BOver-current on string 1Overcurrent string 1 — Overcurrent string 1Details → 0x0A016COver-current on string 2Overcurrent string 2 — Overcurrent string 2Details → 0x0A016DOver-current on string 3Overcurrent string 3 — Overcurrent string 3Details → 0x0A016EOver-current on string 4Overcurrent string 4 — Overcurrent string 4Details → 0x0A016FDefective DC contactorMalfun. DC contactorDetails → 0x0A0171Defective leakage current sensorMalfun. RCD sensor — RCD sensor defectiveDetails → 0x0A0172The auxiliary supply voltage in the power stage is too lowP24V LT aux. supply — P24V supply voltage at the power stack is too low.Details → 0x0A0173The auxiliary supply voltage in the power stage is too lowP5V LT aux. supply — P5V supply voltage at the power stack is too low.Details → 0x0A0174The auxiliary supply voltage in the power stage is too lowP15V LT aux. supply — P15V supply voltage at the power stack is too low.Details → 0x0A0175Fault in the symmetry relaySymmetry relay — Symmetry relay errorDetails → 0x0A0176The switch-on conditions are not metSwitch-on condition — Switch-on condition is not fulfilledDetails → 0x0A0177Fan speed monitoring warningfan E1-E5 — Fan speed-control warningDetails → 0x0A0178Heat sink temperature sensor check for wire break or short circuit KR LTTemp. Sensor KR LT — checking open loop or short loop for temperature sensor cooler rightDetails → 0x0A0179Heat sink temperature sensor check for wire break or short circuit IL LTTemp. Sensor IL LT — checking open loop or short loop for temperature sensor cooling interior leftDetails → 0x0A017AHeat sink temperature sensor check for wire break or short circuit IR LTTemp. Sensor IR LT — checking open loop or short loop for temperature sensor cooling interior rightDetails → 0x0A017BHeat sink temperature sensor check for wire break or short circuit KL LTTemp. Sensor KL LT — checking open loop or short loop for temperature sensor cooler leftDetails → 0x0A017CThe auxiliary supply voltage in the power stage is too lowN15V LT aux. Supply — N15V supply voltage at the power stack is too low.Details → 0x0A017DPhase defectDetails → 0x0A200DOver-temperature — the temperature exceeded the set limit (6)Overtemperature 6 — Device temperature too highDetails → 0x0B0001Error in the error management systemSystem 1 — Error in error management systemDetails → 0x0B0002Error in the error management systemSystem 2 — Error memory is full.Details → 0x0B0003Error in the error management systemSystem 3 — Error acknowledgement has failed.Details → 0x0D0001System error — initialisation failure or operating system crashSystem error — A connection to the power section could not be established during the firmware update.Details → 0x0D0002Defective firmware of the power stageLT bootloader — Power section bootloader faultyDetails → 0x0D0003The device restartedSystem restart — System has been restarted to enable a firmware update to be performed.Details → 0x0E0001Over-current on phase L1 1Overcurrent ph. L1 1 — Overcurrent phase L1Details → 0x0E0002Over-current on phase L2 1Overcurrent ph. L2 1 — Overcurrent phase L2Details → 0x0E0003Over-current on phase L3 1Overcurrent ph. L3 1 — Overcurrent phase L3Details → 0x0E0005Over-current on phase L1 2Overcurrent ph. L1 2 — Overcurrent phase L1Details → 0x0E0006Over-current on phase L2 2Overcurrent ph. L2 2 — Overcurrent phase L2Details → 0x0E0007Over-current on phase L3 2Overcurrent ph. L3 2 — Overcurrent phase L3Details → 0x0E0009Over-current on phase L1 3Overcurrent ph. L1 3 — Overcurrent phase L1Details → 0x0E000AOver-current on phase L2 3Overcurrent ph. L2 3 — Overcurrent phase L2Details → 0x0E000BOver-current on phase L3 3Overcurrent ph. L3 3 — Overcurrent phase L3Details → 0x0E000DTemperature difference between the phase modules is too largePhase temperatures — Temperature difference between the phase modules is too high.Details → 0x0E0013The precharge circuit did not reach the required voltagePreload — Preload cannot reach the preload voltage.Details → 0x0E0015The precharge circuit did not reach the required voltagePreload protection — Preload protection cannot be switched.Details → 0x0E0016The main DC contactor did not switchMain contactor DCDetails → 0x0E0017The main AC contactor did not switchMain contactor ACDetails → 0x0E0018Over-temperature — the temperature exceeded the set limit (4)Overtemperature 4 — Overtemperature at microcontrollerDetails → 0x0E0019The nominal grid voltage is out of rangeGrid voltage 2 — Nominal grid voltage is outside of the grid limits.Details → 0x0E001AThe measured PV voltage is too highSolar cell voltage 1 — The measured DC link voltage of the power section is too high.Details → 0x0E001BThe measured PV voltage is too highSolar cell voltage 2 — The measured solar voltage of the power section is too high.Details → 0x0E001CDefective supply voltage in the power stageSupply voltage — Faulty supply voltage at the power sectionDetails → 0x0E001DOver-temperature — the temperature exceeded the set limit (5)Overtemperature 5 — Overtemperature at controllerDetails → 0x0E001ECommunication error between the power stage and the control unitCommunication SR — Communication malfunction between control and regulation unit and power sectionDetails → 0x0E001FParameter error — defective read, write or parameter fileParameter error — Faulty reading or writing process in power section memoryDetails → 0x0E0020Incorrect installation of the state machineSystem — Finite state machine installed incorrectlyDetails → 0x0E0021External grid protection fault (ENS) active on the digital inputGrid error ENS — An external MSD error is active at digital input X17 Pin1.Details → 0x0E0022The AC switch has not been switched onAC switch — AC switch has not been switched on.Details → 0x0E0023Over-temperature — the temperature exceeded the set limit (8)Overtemperature 8 — Transformer too hotDetails → 0x0E0024Over-current on the DC sideOvercurrent DC — An overcurrent has occurred on the DC side.Details → 0x0E0025Over-temperature — the temperature exceeded the set limit (7)Overtemperature 7 — Overtemperature at power sectionDetails → 0x0E0026Transformer magnetisation failedTransformer magnet. — Transformer magnetisation has failed.Details → 0x0E0027Incorrect DC current measurementDC-current msrt. — Faulty DC-current measurementDetails → 0x0E0028The country code is not set or is invalidCountry of use inv. — The country that has been entered does not exist.Details → 0x0E0029Grid monitoring detected a faultGrid error 1 — The grid is experiencing an MSD error.Details → 0x0E002ADefective power class parameterisationPower classes — Faulty parametrisationDetails → 0x0E002BThe insulation test detected an insulation faultIsolation 1 — Isolation measurement has detected an isolation error before activation.Details → 0x0E002CThe insulation test detected an insulation faultIsolation 2 — Isolation measurement has detected an isolation error during operation.Details → 0x0E002DIncorrect AC current measurementAC-current msrt. — Faulty AC-current measurementDetails → 0x0E002EGrid monitoring detected a faultGrid error 2 — Grid monitoring function has detected an error.Details → 0x0E002FDeviation or limit violation in the DC link voltageDC voltage 1 — The maximum deviation of the DC link voltages has been exceeded.Details → 0x0E0031Defective lightning arresterLightning arrester — Lightning arrester defectiveDetails → 0x0E0032The control limit of the space vector modulation was exceededGrid error RZM — The control limit of the space vector modulation has been exceeded.Details → 0x0E0033Deviation or limit violation in the DC link voltageDC voltage 3 — DC link voltage too lowDetails → 0x0E0034The cooling pump is not working properlyError cooler pump — Cooler pump is not functioning correctly.Details → 0x0E0035Over-current detectedOvercurrent 5 — Overcurrent has been detected.Details → 0x0E0036Over-current detectedOvercurrent 6 — Overcurrent has been detected.Details → 0x0E0037Deviation or limit violation in the DC link voltageDC voltage 4 — The maximum deviation of the DC link voltages has been exceeded.Details → 0x0E0038Grid monitoring detected a faultGrid error — Grid monitoring function has detected an error.Details → 0x0E0039Over-temperature — the temperature exceeded the set limitOvertemperature — Mains line choke cores are very hot as very little cooling air is available.Details → 0x0E0050Over-current detectedOvercurrent 1 — Overcurrent gridDetails → 0x0E0051Over-current detectedOvercurrent 2 — Overcurrent power section 2Details → 0x0E0052Over-current detectedOvercurrent 3 — Overcurrent power section 1Details → 0x0E0053Over-current detectedOvercurrent 4 — Overcurrent DCDetails → 0x0E0100Fault message from the power stageFault message LT — Fault message from power sectionDetails → 0x0F0100Grid disturbance (stability, inrush current or load) — lowGrid stabillity lowDetails → 0x0F0101Grid disturbance (stability, inrush current or load) — highGrid stabillity highDetails → 0x0F0102Grid disturbance (stability, inrush current or load)Grid inrushDetails → 0x0F0103Grid disturbance (stability, inrush current or load)Grid flickersDetails → 0x0F0104Grid disturbance (stability, inrush current or load)Grid high overloadDetails → 0x0F0105Grid disturbance (stability, inrush current or load)Grid low overloadDetails → 0x0F0106Grid disturbance (stability, inrush current or load)Grid pos underloadDetails → 0x0F0107Grid disturbance (stability, inrush current or load)Grid neg underloadDetails → 0x100001Problem with the Ethernet connectionEthernet connectn. 1 — A connection to the ethernet could not be established.Details → 0x100002Problem with the Ethernet connectionEthernet connectn. 2 — Loss of ethernet connectionDetails → 0x100003Problem with the Ethernet connectionEthernet connectn. 3 — No 100Mbit/s ethernet connection is available.Details → 0x100004Name resolution failed — the data was nevertheless sent normallyDNS error — The name resolution of the port address failed. However, the data was successfully transmitted.Details → 0x100010General error in the data transfer to the monitoring portalPortal error 1 — General error in data transferDetails → 0x100011General error in the data logger unitData logger error 1 — General error in data storage module.Details → 0x100012General error in the data logger unitData logger error 2 — General error in data storage module.Details → 0x100013Internal protection function (watchdog) was triggeredWatchdog error — Internal protection function was triggered.Details → 0x100014Program memory protection error (memcpy)MMU memcpy — Internal protection function was triggered.Details → 0x20002Deviation or limit violation in the DC link voltageDC voltage 2 — DC link voltage too high: The DC link voltage is above the max. limit.Details → 0x20003Wrong phase rotation (clockwise rotating field)Anticlockws.rot.fld. — The clockwise rotating field of the voltage supply is faulty.Details → 0x20004The grid current exceeded the maximum limit on one of the three phasesOvercurrent — The mains current is above the max. AC-current limit in one of the three phases.Details → 0x30002Parameter error — defective read, write or parameter fileParameter error 1 — A defective parameter file was found when the special functions were initialised.Details → 0x30005Parameter error — defective read, write or parameter fileParameter error 2 — No parameter file was found when the special functions were initialised.Details → 0x30006Parameter error — defective read, write or parameter fileParameter error 3 — The number of parameters does not correspond to the number of parameters in the file system.Details → 0x40001Communication timeout between the control board and the power stageInternal communictn. — Timeout between control and regulation unit card and power sectionDetails → 0x40010System error — initialisation failure or operating system crashSystem error 1 — Operating system crashDetails → 0x50000System error — initialisation failure or operating system crashSystem error 2 — Initialisation has failed.Details → 0x60001The inverter is feeding in with the wrong time — the clock was not initialisedIncorrect time — Inverter is feeding in with incorrect time as real-time clock has not been initialised.Details → 0x70000The firmware update could not start — another update is in progressUpdate registration — An additional update could not be registered.Details → 0x70001The firmware update could not start — another update is in progressUpdate in progress — An update is already in progress.Details → 0x80001The inverter is feeding in with the wrong time — the clock was not initialisedIncorrect time — Initialisation of real-time clock has failed. This prevents data logger from functioning.Details → 0x90001The device restartedSystem restart — The inverter has been restarted.Details → 0x90002The program checksums do not matchProgram CRC error — Checksums do not correspond.Details → 0x90003System restart by the watchdog circuitSR watchdog reset — System reset performed by watchdog.Details → 0x90004RAM error in a critical safety variableRAM error 1 — RAM error detected in a safety-critical variableDetails → 0x90005Program memory protection error (exception)MMU exception — Program memory protection faultDetails → 0xA20000Communication error with the string combiner box (SCB)GAK comm. failure — Indicates communication failure of a string connection box (SCB).Details →