1What the error means
The following error codes of REFUsol inverters belong to the same fault family: DC link. Find the code shown by your inverter in the table and see what it means.
2Possible causes
- Worn or dried-out DC link capacitors
- Fault in the boost converter circuit
- Sudden voltage changes
3What to do
- One restart with AC and DC switched off.
- If it returns, the DC link capacitors need to be checked and usually replaced.
The codes in detail
| Code | What it means |
|---|---|
| 0x09000A | Fault in the DC link |
| 0x09000B | Fault in the DC link |
| 0x09000C | Fault in the DC link |
| 0x09000D | Fault in the DC link |
| 0x09000F | Voltage fault in the regulator circuit / DC link 13 |
| 0x090010 | Fault in the DC link |
| 0x090011 | Fault in the DC link |
| 0x090060 | Grid instability handled according to the grid code |
| 0x0A0001 | Voltage fault in the regulator circuit / DC link 1 |
| 0x0A0002 | Voltage fault in the regulator circuit / DC link 2 |
| 0x0A0003 | Voltage fault in the regulator circuit / DC link 3 |
| 0x0A0004 | Voltage fault in the regulator circuit / DC link 4 |
| 0x0A0005 | Voltage fault in the regulator circuit / DC link 5 |
| 0x0A0006 | Voltage fault in the regulator circuit / DC link 6 |
| 0x0A0007 | Voltage fault in the regulator circuit / DC link 7 |
| 0x0A0008 | Voltage fault in the regulator circuit / DC link 8 |
| 0x0A0009 | Voltage fault in the regulator circuit / DC link 9 |
| 0x0A000A | Voltage fault in the regulator circuit / DC link 10 |
| 0x0A000B | Voltage fault in the regulator circuit / DC link 11 |
| 0x0A000C | Voltage fault in the regulator circuit / DC link 12 |
| 0x0A0110 | Shutdown of the power stage due to DC over-voltage |
| 0x0A0111 | Shutdown of the power stage due to DC over-voltage |
| 0x0A011A | Failure in the activation sequence of the power stage |
| 0x0A011B | Failure in the activation sequence of the power stage |
| 0x0A011C | Failure in the activation sequence of the power stage |
| 0x0A011D | Failure in the activation sequence of the power stage |
| 0x0A011E | Failure in the activation sequence of the power stage |
| 0x0A0160 | Error during precharging |
| 0x0A0166 | Over-voltage in the DC link |
| 0x0A0167 | Over-voltage in the DC link |
| 0x0A016A | Asymmetric power output on the three phases |
| 0x0E0013 | The precharge circuit did not reach the required voltage |
| 0x0E0015 | The precharge circuit did not reach the required voltage |
| 0x0E001A | The measured PV voltage is too high |
| 0x0E001B | The measured PV voltage is too high |
| 0x0E002F | Deviation or limit violation in the DC link voltage |
| 0x0E0033 | Deviation or limit violation in the DC link voltage |
| 0x0E0037 | Deviation or limit violation in the DC link voltage |
| 0x20002 | Deviation or limit violation in the DC link voltage |
4Repair by Aineas
You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.