REFUsol — DC link

Intermediate circuit (DC link)

Error code
39 codes
Category
Intermediate circuit (DC link)
Manufacturer
REFUsol

1What the error means

The following error codes of REFUsol inverters belong to the same fault family: DC link. Find the code shown by your inverter in the table and see what it means.

2Possible causes

  • Worn or dried-out DC link capacitors
  • Fault in the boost converter circuit
  • Sudden voltage changes

3What to do

  1. One restart with AC and DC switched off.
  2. If it returns, the DC link capacitors need to be checked and usually replaced.

The codes in detail

CodeWhat it means
0x09000AFault in the DC link
0x09000BFault in the DC link
0x09000CFault in the DC link
0x09000DFault in the DC link
0x09000FVoltage fault in the regulator circuit / DC link 13
0x090010Fault in the DC link
0x090011Fault in the DC link
0x090060Grid instability handled according to the grid code
0x0A0001Voltage fault in the regulator circuit / DC link 1
0x0A0002Voltage fault in the regulator circuit / DC link 2
0x0A0003Voltage fault in the regulator circuit / DC link 3
0x0A0004Voltage fault in the regulator circuit / DC link 4
0x0A0005Voltage fault in the regulator circuit / DC link 5
0x0A0006Voltage fault in the regulator circuit / DC link 6
0x0A0007Voltage fault in the regulator circuit / DC link 7
0x0A0008Voltage fault in the regulator circuit / DC link 8
0x0A0009Voltage fault in the regulator circuit / DC link 9
0x0A000AVoltage fault in the regulator circuit / DC link 10
0x0A000BVoltage fault in the regulator circuit / DC link 11
0x0A000CVoltage fault in the regulator circuit / DC link 12
0x0A0110Shutdown of the power stage due to DC over-voltage
0x0A0111Shutdown of the power stage due to DC over-voltage
0x0A011AFailure in the activation sequence of the power stage
0x0A011BFailure in the activation sequence of the power stage
0x0A011CFailure in the activation sequence of the power stage
0x0A011DFailure in the activation sequence of the power stage
0x0A011EFailure in the activation sequence of the power stage
0x0A0160Error during precharging
0x0A0166Over-voltage in the DC link
0x0A0167Over-voltage in the DC link
0x0A016AAsymmetric power output on the three phases
0x0E0013The precharge circuit did not reach the required voltage
0x0E0015The precharge circuit did not reach the required voltage
0x0E001AThe measured PV voltage is too high
0x0E001BThe measured PV voltage is too high
0x0E002FDeviation or limit violation in the DC link voltage
0x0E0033Deviation or limit violation in the DC link voltage
0x0E0037Deviation or limit violation in the DC link voltage
0x20002Deviation or limit violation in the DC link voltage

4Repair by Aineas

You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.