+30 2310 607032 · info@aineas.gr · Mon–Fri 09:00–17:00
Services The lab How it works Inverter Errors Contact thesolarportal.com thesolarlink. →

REFUsol — Over-temperature

Overtemperature

Error code
27 codes
Category
Overtemperature
Manufacturer
REFUsol

1What the error means

The following error codes of REFUsol inverters belong to the same fault family: over-temperature. Find the code shown by your inverter in the table and see what it means.

2Possible causes

  • Dirty or blocked heat sinks and fans
  • Installation in an enclosed space without ventilation or in direct sun
  • Faulty fan or temperature sensor

3What to do

  1. Clean the heat sinks and check that the fans are turning.
  2. Ensure ventilation and shade at the installation site.
  3. If the fault appears with the unit cold, the sensor or the fan needs to be replaced.

The codes in detail

CodeWhat it means
0x0A0102Over-temperature in the power stage (sensor 1)
0x0A0103Over-temperature in the power stage (sensor 2)
0x0A0104Over-temperature in the power stage (sensor 3)
0x0A0105Over-temperature in the power stage (sensor 4)
0x0A0150Over-temperature — the temperature exceeded the set limit (2)
0x0A0151Over-temperature — the temperature exceeded the set limit (AC1)
0x0A0152Over-temperature — the temperature exceeded the set limit (AC2)
0x0A0153Over-temperature — the temperature exceeded the set limit (inner)
0x0A0154Over-temperature on the heat sink of boost converter 1
0x0A0155Over-temperature on the heat sink of boost converter 2
0x0A0156Over-temperature — the temperature exceeded the set limit (U)
0x0A0157Over-temperature — the temperature exceeded the set limit (V)
0x0A0158Over-temperature — the temperature exceeded the set limit (W)
0x0A015EWire break in the heat sink temperature sensor
0x0A015FShort circuit in the heat sink temperature sensor
0x0A0178Heat sink temperature sensor check for wire break or short circuit KR LT
0x0A0179Heat sink temperature sensor check for wire break or short circuit IL LT
0x0A017AHeat sink temperature sensor check for wire break or short circuit IR LT
0x0A017BHeat sink temperature sensor check for wire break or short circuit KL LT
0x0A200DOver-temperature — the temperature exceeded the set limit (6)
0x0E000DTemperature difference between the phase modules is too large
0x0E0018Over-temperature — the temperature exceeded the set limit (4)
0x0E001DOver-temperature — the temperature exceeded the set limit (5)
0x0E0023Over-temperature — the temperature exceeded the set limit (8)
0x0E0025Over-temperature — the temperature exceeded the set limit (7)
0x0E0034The cooling pump is not working properly
0x0E0039Over-temperature — the temperature exceeded the set limit

4Repair by Aineas

You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.

← All REFUsol errors