- Error code
- 27 codes
- Category
- Overtemperature
- Manufacturer
- REFUsol
1What the error means
The following error codes of REFUsol inverters belong to the same fault family: over-temperature. Find the code shown by your inverter in the table and see what it means.
2Possible causes
- Dirty or blocked heat sinks and fans
- Installation in an enclosed space without ventilation or in direct sun
- Faulty fan or temperature sensor
3What to do
- Clean the heat sinks and check that the fans are turning.
- Ensure ventilation and shade at the installation site.
- If the fault appears with the unit cold, the sensor or the fan needs to be replaced.
The codes in detail
| Code | What it means |
|---|---|
| 0x0A0102 | Over-temperature in the power stage (sensor 1) |
| 0x0A0103 | Over-temperature in the power stage (sensor 2) |
| 0x0A0104 | Over-temperature in the power stage (sensor 3) |
| 0x0A0105 | Over-temperature in the power stage (sensor 4) |
| 0x0A0150 | Over-temperature — the temperature exceeded the set limit (2) |
| 0x0A0151 | Over-temperature — the temperature exceeded the set limit (AC1) |
| 0x0A0152 | Over-temperature — the temperature exceeded the set limit (AC2) |
| 0x0A0153 | Over-temperature — the temperature exceeded the set limit (inner) |
| 0x0A0154 | Over-temperature on the heat sink of boost converter 1 |
| 0x0A0155 | Over-temperature on the heat sink of boost converter 2 |
| 0x0A0156 | Over-temperature — the temperature exceeded the set limit (U) |
| 0x0A0157 | Over-temperature — the temperature exceeded the set limit (V) |
| 0x0A0158 | Over-temperature — the temperature exceeded the set limit (W) |
| 0x0A015E | Wire break in the heat sink temperature sensor |
| 0x0A015F | Short circuit in the heat sink temperature sensor |
| 0x0A0178 | Heat sink temperature sensor check for wire break or short circuit KR LT |
| 0x0A0179 | Heat sink temperature sensor check for wire break or short circuit IL LT |
| 0x0A017A | Heat sink temperature sensor check for wire break or short circuit IR LT |
| 0x0A017B | Heat sink temperature sensor check for wire break or short circuit KL LT |
| 0x0A200D | Over-temperature — the temperature exceeded the set limit (6) |
| 0x0E000D | Temperature difference between the phase modules is too large |
| 0x0E0018 | Over-temperature — the temperature exceeded the set limit (4) |
| 0x0E001D | Over-temperature — the temperature exceeded the set limit (5) |
| 0x0E0023 | Over-temperature — the temperature exceeded the set limit (8) |
| 0x0E0025 | Over-temperature — the temperature exceeded the set limit (7) |
| 0x0E0034 | The cooling pump is not working properly |
| 0x0E0039 | Over-temperature — the temperature exceeded the set limit |