+30 2310 607032 · info@aineas.gr · Mon–Fri 09:00–17:00
Services The lab How it works Inverter Errors Contact thesolarportal.com thesolarlink. →

REFUsol — Communication

Communication

Error code
16 codes
Category
Communication
Manufacturer
REFUsol

1What the error means

The following error codes of REFUsol inverters belong to the same fault family: communication. Find the code shown by your inverter in the table and see what it means.

2Possible causes

  • Fault on the internal communication bus between the boards
  • Loose internal wiring
  • Damage from overvoltage

3What to do

  1. One restart with AC and DC switched off.
  2. If it returns, the boards need to be checked in our lab.

The codes in detail

CodeWhat it means
0x090017Communication error between the power stage and the control unit
0x09002AInternal communication monitoring detected an error
0x090031The Ethernet cable was disconnected
0x090053Communication error between the power stage and the control unit
0x0A0120Communication error between the power stage and the control unit
0x0E001ECommunication error between the power stage and the control unit
0x100001Problem with the Ethernet connection
0x100002Problem with the Ethernet connection
0x100003Problem with the Ethernet connection
0x100004Name resolution failed — the data was nevertheless sent normally
0x100010General error in the data transfer to the monitoring portal
0x100011General error in the data logger unit
0x100012General error in the data logger unit
0x40001Communication timeout between the control board and the power stage
0x80001The inverter is feeding in with the wrong time — the clock was not initialised
0xA20000Communication error with the string combiner box (SCB)

4Repair by Aineas

You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.

← All REFUsol errors