REFUsol — Leakage current

Leakage current

Error code
4 codes
Category
Leakage current
Manufacturer
REFUsol

1What the error means

The following error codes of REFUsol inverters belong to the same fault family: leakage current. Find the code shown by your inverter in the table and see what it means.

2Possible causes

  • Ground fault in the PV generator
  • Moisture in the installation
  • Faulty module or cable
  • Fault in the inverter's residual current sensor

3What to do

  1. Check the PV generator for a ground fault, especially after rain.
  2. Measure the insulation resistance.
  3. If the fault also appears with the PV generator disconnected, the fault is in the inverter.

The codes in detail

CodeWhat it means
0x09001BThe RCD circuit detected leakage current — immediate disconnection
0x09001DThe RCD circuit detected leakage current — warning with immediate disconnection
0x0A0115The RCD circuit detected leakage current — warning with immediate disconnection
0x0A0171Defective leakage current sensor

4Repair by Aineas

You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.