+30 2310 607032 · info@aineas.gr · Mon–Fri 09:00–17:00
Services The lab How it works Inverter Errors Contact thesolarportal.com thesolarlink. →

REFUsol — Fan

Fan

Error code
6 codes
Category
Fan
Manufacturer
REFUsol

1What the error means

The following error codes of REFUsol inverters belong to the same fault family: fan. Find the code shown by your inverter in the table and see what it means.

2Possible causes

  • Blocked by dust or a foreign object
  • Worn bearing
  • Fault in the fan's supply circuit

3What to do

  1. Clean the fan and the heat sinks.
  2. Check whether it turns freely.
  3. If it does not run, it needs to be replaced — otherwise overtemperature will follow.

The codes in detail

CodeWhat it means
0x0A0159Fault in fan 1
0x0A015AFault in fan 2
0x0A015BFault in fan 3
0x0A015CFault in fan 4
0x0A015DFault in fan 5
0x0A0177Fan speed monitoring warning

4Repair by Aineas

You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.

← All REFUsol errors