REFUsol — Insulation fault

Insulation resistance

Error code
9 codes
Category
Insulation resistance
Manufacturer
REFUsol

1What the error means

The following error codes of REFUsol inverters belong to the same fault family: insulation fault. Find the code shown by your inverter in the table and see what it means.

2Possible causes

  • Moisture in junction boxes, connectors or modules
  • Damaged or worn DC cables
  • Faulty module

3What to do

  1. Note whether it appears after rain or early in the morning.
  2. Measure the insulation resistance of each string to earth.
  3. Check connectors and junction boxes for moisture.
  4. If the PV generator is fine, check the inverter's measuring circuit.

The codes in detail

CodeWhat it means
0x090063No change in the insulation current was measured during the test
0x0A0013The measured leakage current exceeded the safety limits
0x0A010CThe power stage detected an insulation fault during activation
0x0A010DThe RCD circuit detected leakage current — immediate disconnection
0x0A0114The measured leakage current exceeded the safety limits
0x0A0117The insulation test is taking too long
0x0A0169Wire break in the insulation sensor
0x0E002BThe insulation test detected an insulation fault
0x0E002CThe insulation test detected an insulation fault

4Repair by Aineas