- Error code
- 11 codes
- Category
- Parameters
- Manufacturer
- REFUsol
1What the error means
The following error codes of REFUsol inverters belong to the same fault family: parameters and country code. Find the code shown by your inverter in the table and see what it means.
2Possible causes
- Wrong or corrupted parameter file
- Incomplete firmware update
- Memory fault
3What to do
- Check that the correct country setting is selected.
- If the parameters do not load, the control board needs to be reset or replaced.
The codes in detail
| Code | What it means |
|---|---|
| 0x090024 | Error during parameter initialisation — the device was permanently shut down |
| 0x0A0014 | The country code is not set or is invalid |
| 0x0A0017 | The country code is not set or is invalid |
| 0x0A0113 | The country code does not match the country sub-code |
| 0x0A011F | Parameter error — defective read, write or parameter file |
| 0x0E001F | Parameter error — defective read, write or parameter file |
| 0x0E0028 | The country code is not set or is invalid |
| 0x0E002A | Defective power class parameterisation |
| 0x30002 | Parameter error — defective read, write or parameter file |
| 0x30005 | Parameter error — defective read, write or parameter file |
| 0x30006 | Parameter error — defective read, write or parameter file |
4Repair by Aineas
You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.