Kostal Piko and Errors

Manufacturer
KOSTAL
Models
Piko

1What the error means

On many Kostal inverters, at around 100,000 kWh, errors appear that are related to the incorrect operation of your inverter.

2Possible solution

Try switching off the grid breaker and switching it back on after 2-3 minutes. If the problem persists, you will need to send us the inverter for repair. Below is an indicative list of the possible errors that may appear on Kostal inverters. It is always recommended to consult the user manual of your inverter.
106 Neutral not connected
150 Frequency fault
151 – 164 Grid fault at start-up
165 – 178 Frequency fault
240-241 AC fault
250 Grid voltage out of range
251 – 278 Grid problem
279 – 292 Phase interruption not correct
300 – 399 Shutdown due to leakage current
400 – 401 PV Over Voltage
601 – 615 Overtemperature
800 – 999 Internal fault

3What to do

  1. Note the code and the inverter model (nameplate on the side of the unit).
  2. Switch off the grid (AC) breaker and switch it on again after 2–3 minutes.
  3. If the error returns or keeps recurring, do not keep restarting the unit — contact us for a diagnosis.

4Repair by Aineas

You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.

← All KOSTAL errors