Overtemperature

Error code
601–615
Category
Overtemperature
Manufacturer
KOSTAL
Models
Piko / Plenticore

1What the error means

Overtemperature. The temperature inside the inverter exceeded the limit and the power was reduced or operation stopped until it cools down. Codes 601 to 615 show which point overheated.

2Possible causes

  • Dirty or blocked heat sinks and fans
  • Installation in an enclosed space without ventilation or in direct sun
  • Faulty fan or temperature sensor

3What to do

  1. Clean the heat sinks and check that the fans are turning.
  2. Ensure ventilation and shade at the installation site.
  3. If the fault appears with the unit cold, the sensor or the fan needs to be replaced.

Codes covered

This fault appears with the codes 601–615. The manufacturer documents them as a single fault — the number indicates the stage or the phase in which it was detected.