+30 2310 607032 · info@aineas.gr · Mon–Fri 09:00–17:00
Services The lab How it works Inverter Errors Contact thesolarportal.com thesolarlink. →

ABB / FIMER W011 — Sun Low

Low DC voltage

Error code
W011
Category
Low DC voltage
Manufacturer
ABB / FIMER

1What the error means

Low voltage in the DC link (bulk under-voltage) due to insufficient power from the generator. Usually appears in low sunlight.

On the display or in the monitoring software it appears as Sun Low.

2Possible causes

  • Low solar irradiance — morning, evening or overcast
  • Shading or soiling of the modules
  • Broken DC cable or faulty string
  • DC switch open

3What to do

  1. If it appears only at the start and end of the day, it is normal.
  2. Check that the DC switch is closed.
  3. Measure voltage and current on each string in sunshine.
  4. Check for shading, dirty modules and damaged DC connectors.

4Repair by Aineas

You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.

← All ABB / FIMER errors