ABB / FIMER E018 — Ground F.

Leakage current

Error code
E018
Category
Leakage current
Manufacturer
ABB / FIMER

1What the error means

Leakage current fault. The inverter measured a leakage current to earth above the permitted level and disconnected.

On the display or in the monitoring software it appears as Ground F..

2Possible causes

  • Ground fault in the PV generator
  • Moisture in the installation
  • Faulty module or cable
  • Fault in the inverter's residual current sensor

3What to do

  1. Check the PV generator for a ground fault, especially after rain.
  2. Measure the insulation resistance.
  3. If the fault also appears with the PV generator disconnected, the fault is in the inverter.

4Repair by Aineas

You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.