- Error code
- E018
- Category
- Leakage current
- Manufacturer
- ABB / FIMER
1What the error means
Leakage current fault. The inverter measured a leakage current to earth above the permitted level and disconnected.
On the display or in the monitoring software it appears as Ground F..
2Possible causes
- Ground fault in the PV generator
- Moisture in the installation
- Faulty module or cable
- Fault in the inverter's residual current sensor
3What to do
- Check the PV generator for a ground fault, especially after rain.
- Measure the insulation resistance.
- If the fault also appears with the PV generator disconnected, the fault is in the inverter.