+30 2310 607032 · info@aineas.gr · Mon–Fri 09:00–17:00
Services The lab How it works Inverter Errors Contact thesolarportal.com thesolarlink. →

ABB / FIMER E015 — Cap. Fault

Intermediate circuit (DC link)

Error code
E015
Category
Intermediate circuit (DC link)
Manufacturer
ABB / FIMER

1What the error means

Fault in the DC link capacitors. One of the most common forms of wear in inverters after years of operation.

On the display or in the monitoring software it appears as Cap. Fault.

2Possible causes

  • Worn or dried-out DC link capacitors
  • Fault in the boost converter circuit
  • Sudden voltage changes

3What to do

  1. One restart with AC and DC switched off.
  2. If it returns, the DC link capacitors need to be checked and usually replaced.

4Repair by Aineas

You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.

← All ABB / FIMER errors