+30 2310 607032 · info@aineas.gr · Mon–Fri 09:00–17:00
Services The lab How it works Inverter Errors Contact thesolarportal.com thesolarlink. →

ABB / FIMER E020 — Int. Error

Grid relay

Error code
E020
Category
Grid relay
Manufacturer
ABB / FIMER

1What the error means

Fault in the DC/DC circuit relay. The relay did not respond as expected during the check.

On the display or in the monitoring software it appears as Int. Error.

2Possible causes

  • Stuck or burnt relay contacts
  • Fault in the relay drive circuit
  • Wear after many switching cycles

3What to do

  1. One restart with AC and DC switched off.
  2. If it returns, the relays need to be replaced in our lab.

4Repair by Aineas

You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.