+30 2310 607032 · info@aineas.gr · Mon–Fri 09:00–17:00
Services The lab How it works Inverter Errors Contact thesolarportal.com thesolarlink. →

Sungrow Error 038

Grid relay

Error code
038
Category
Grid relay
Manufacturer
SUNGROW
Models
SG80KTL / SG110 / SG250 / SG350

1What the error means

The test of the relays that connect the inverter to the grid failed and the inverter does not connect. On the SG80KTL the manufacturer documents it as “Relay Fault on the Grid Side”; on the SG110, SG250 and SG350 as “Permanent Relay Fault” — a permanent relay fault that does not clear with a restart.

2Possible causes

  • Stuck or burnt relay contacts
  • Fault in the relay drive circuit
  • Wear after many switching cycles

3What to do

  1. Switch off AC and DC, wait 2–3 minutes and restart once.
  2. If the code returns immediately, it is a permanent relay fault and cannot be fixed on site.
  3. We take on fault 38: the relays and their drive circuit are checked and replaced in our lab in Thessaloniki.

4Repair by Aineas

You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.

← All SUNGROW errors