+30 2310 607032 · info@aineas.gr · Mon–Fri 09:00–17:00
Services The lab How it works Inverter Errors Contact thesolarportal.com thesolarlink. →

Sungrow Error 021

DC overcurrent

Error code
021
Category
DC overcurrent
Manufacturer
SUNGROW

1What the error means

PV1 input overcurrent (PV1 Input Over-current): the current on the first DC input exceeded the maximum permitted.

2Possible causes

  • Incorrect string sizing — too much current
  • Short circuit on the DC side
  • Fault in the inverter's input circuit

3What to do

  1. Measure the current of each string and compare it with the inverter's limit.
  2. Check the DC cables for a short circuit.
  3. If the PV generator is fine, the input stage needs to be checked in our lab.

4Repair by Aineas

You send the inverter to our lab in Thessaloniki. We diagnose it, inform you of the fault and the cost, and the repair starts only after you approve it. Every inverter is tested under simulated operating conditions before delivery.

← All SUNGROW errors